GFDD370-150 Dry-type transformer cross-currentCooling Fans   Recommended models are: GFDD470-110 GFDD470-150 GFDD470-90 GFDD370-110 GFDD370-90 and other models, manufacturers of general, reasonable price, the specific price of the contact phone: 400-181-6499

GF series cross-flow cooling fans for dry-type transformers
1, this series of cross-flow cooling fan, using advanced cross-flow mechanism, with microtek motor rotation, widely used in dry-type transformer, electric control frame, etc., can greatly improve the transformer and other products of the over-negative operating capacity.
2、Yingnuo production of GF series fan by the country's dry-type transformer factory trust, product specifications complete (30KVA-20000 capacity of dry-type transformer can be used), each dry-type transformer depending on the size of the capacity can be configured to cool the fan, and its main types There are two kinds of.
(1) Side blower; (2) Top blowing blower
3, the factory produces the GF series of fans all use high-strength plate and with professional manufacturers of high-quality bearings made of motor, durable, reliable quality, excellent performance, its advantages.
(1) Low energy consumption, large air volume, good cooling effect.
(2) Beautiful modeling, reasonable structure, easy installation, firm and reliable.
(3) Low vibration, low noise, balanced motion and long service life.
GFDD370-150 Cooling fan technical parameters
  • input voltage: 220V
  • power (output): 50W
  • air volume: larger, exact value varies by manufacturer
  • static (in a signal): Low noise design for smooth operation
  • Operating Temperature Range: -40℃~75℃
  • Installation: Usually installed on both sides of the lower part of the transformer coil, blowing cold air directly into the transformer's high and low voltage cooling ducts.
  • material (that sth is made of): High-quality materials with good corrosion resistance

Product Features

  • Highly efficient heat dissipation: By increasing the diameter of the wind impeller, the airflow is significantly increased, effectively reducing the temperature of the transformer.
  • low noise: The noise elimination parts are added to the air outlet to effectively control the noise generated by the high-speed airflow.
  • structurally sound: Fully enclosed design prevents foreign objects from entering and reduces the risk of failure.
  • high reliability: Adopt famous motor and high quality bearings to ensure long-term stable operation.
  • adaptableThe dry-type transformer can be adapted to a variety of capacities to meet the needs of different users.

application scenario

  • Dry-type transformer cooling: It is mainly used for forced air cooling of dry-type transformers, which can significantly improve the heat dissipation efficiency of the transformer and prolong its service life.
  • run at increased capacity: With the use of this fan, the output power of the dry-type transformer can be increased by 40-50%, thus increasing the carrying capacity of the transformer.
  • Other equipment coolingIt can also be used for cooling of high and low voltage distribution cabinets, switch cabinets, electronic equipment, and so on.

Installation and use

  • mounting position: Usually mounted on both sides of the lower part of the transformer coil to ensure that cold air is blown directly into the cooling ducts.
  • Environmental requirements: The gas passing through the fan should be free of strong acids, alkalis and various solutions to avoid sand, dust and other debris from entering the interior of the fan.
  • Maintenance: Regularly check the operating status of the fan, clean up dust and debris to ensure normal operation of the fan.
Part of the model show
gfdd358-110 220v,gfdd358-120 220v,gfdd365-110 220v,gfdd365-120 220v,gfdd370-110 220v,gfdd370-120 220v,gfdd385-110 220v,gfdd385-120 220v,gfdd440-110 220v,gfdd440-120 220v,gfdd470-110 220v,gfdd470-120 220v,gfdd490-110 220v,gfdd490-120 220v,gfdd520-110 220v,gfdd520-120 220v,gfdd560-110 220v,GFDD560-120 220V,gfdd570-110 220v,gfdd570-120 220v,gfdd582-110 220v,gfd582-120 220v,gfdd590-110 220v,gfdd590-120 220v,gfdd610-110 220v,gfdd610-120 220v,gfdd650-110 220v,gfdd650-120 220v,gfdd660-110 220v,gfdd660-120 220v,gfdd670-110 220v,gfdd670-120 220v,gfdd690-110 220v,gfdd690-120 220v,gfdd700-110 220v,GFDD700-120 220V,gfdd710-110 220v,GFDD710-120 220V,GFDD750-110 220V,GFDD750-120 220V,gfdd760-110 220v,gfdd760-120 220v,gfdd470-150 220v,gfdd470-155 220v,gfdd590-150 220v,GFDD590-155 220V, etc., further informationGFDD370-150Specific parameters for cooling fans orContact us for more modelsPurchase Information.

Example: GFDD470-150: indicates single-phase 220V, fan total length of 470mm, impeller diameter of 150mm top blowing dry-type transformers with cross-flow cooling fan

Top-blown cooling fan models External and mounting dimensions

Dry-type transformer cooling fan size

Appearance and Installation dimension of top blowing blower

Specification
Specification
A A1 B B1 L L1 L2 mounting hole
Mounting hole
GFD(s) D370-120 150 120 160 120 370 330 310 4-Φ7×11
GFD(s) D385-120 150 120 160 120 385 345 325 4-Φ7×11
GFD(s) D420-120 150 120 160 120 420 380 360 4-Φ7×11
GFD(s) D440-120 150 120 160 120 440 400 380 4-Φ7×11
GFD(s) D470-120 150 120 160 120 470 430 410 4-Φ7×11
GFD(s) D490-120 150 120 160 120 490 450 430 4-Φ7×11
GFD(s) D520-120 150 120 160 120 520 480 460 4-Φ7×11
GFD(s) D560-120 150 120 160 120 560 520 500 4-Φ7×11
GFD(s) D590-120 150 120 160 120 590 550 530 4-Φ7×11
GFD(s) D6W-120 150 120 160 120 610 570 550 4-Φ7×11
GFD(s) D700-120 150 120 160 120 700 660 640 4-Φ7×11
GFD(s) D760-120 150 120 160 120 760 720 700 4-Φ7×11
GFD(s) D780-120 150 120 160 120 780 740 720 4-Φ7×11
GFD(s) D810-120 150 120 160 120 810 770 750 4-Φ7×11
GFD(s) D850-120 150 120 160 120 850 810 790 4-Φ7×11
GFD(s) D920-120 150 120 160 120 920 880 860 4-Φ7×11
GFD(s) D1020-120 150 120 160 120 1020 980 960 4-Φ7×11
GFD(s) D1120-120 150 120 160 120 1120 1080 1060 4-Φ7×11
GFD(s) D1200-120 150 120 160 120 1200 1160 1140 4-Φ7×11
GFD(s) D1220-120 150 120 160 120 1220 1180 1160 4-Φ7×11
GFD(s) D1300-120 150 120 160 120 1300 1260 1240 4-Φ7×11
GFD(s) D1400-120 150 120 160 120 1400 1360 1340 4-Φ7×11
GFD(s) D370-155/150 195 160 185 120 370 325 305 4-Φ7×11
GFD(s) D420-155/150 195 160 185 120 420 380 360 4-Φ7×11
GFD(s) D470-155/150 195 160 185 120 470 430 410 4-Φ7×11
GFD(s) D490-155/150 195 160 185 120 490 450 430 4-Φ7×11
GFD(s) D590-155/150 195 160 185 120 590 550 530 4-Φ7×11
GFD(s) D650-155/150 195 160 185 120 650 610 590 4-Φ7×11
GFD(s) D780-155/150 195 160 185 120 780 740 720 4-Φ7×11
GFD(s) D850-155/150 195 160 185 120 850 810 790 4-Φ7×11
GFD(s) D650-200 250 200 250 200 650 585 565 4-Φ7×11
GFD(s) D780-200 250 200 250 200 780 695 675 4-Φ7×11
GFD(s) D850-200 250 200 250 200 850 700 680 4-Φ7×11
GFD(s) D950-200 250 200 250 200 950 810 790 4-Φ7×11
GFD(s) D1180-200 250 200 250 200 1180 1050 1030 4-Φ7×11
GFD(s) D1300-200 250 200 250 200 1300 1170 1150 4-Φ7×11

 

 Dry-type transformer cooling fan model Performance parameters

Model Specification Motor parameters air volume
(m³/h)
static (in a signal)
dB(A)
Transformer capacity Number of units
Voltage (V) phase (math.) frequency
(Hz)
Current (A) power (output)
(W)
number of revolutions per minute
(r/min)
GFD(s) D370-120 220/380 Single/Triple 50 0.24/0.15 45 1400 700 <50 315-500 6
GFD(s) D385-120 220/380 Single/Triple 50 0.24/0.15 45 1400 710 <50 315-500 6
GFD(s) D420-120 220/380 Single/Triple 50 0.24/0.15 50 1400 720 <50 400-800 6
GFD(s) D440-120 220/380 Single/Triple 50 0.24/0.15 50 1400 750 <50 400-1000 6
GFD(s) D470-120 220/380 Single/Triple 50 0.24/0.15 50 1400 810 <50 800-1250 6
GFD(s) D490-120 220/380 Single/Triple 50 0.24/0.15 50 1400 850 <50 1000-1600 6
GFD(s) D520-120 220/380 Single/Triple 50 0.25/0.15 55 1400 870 <50 1250-1600 6
GFD(s) D560-120 220/380 Single/Triple 50 0.25/0.15 55 1400 900 <50 1250-2000 6
GFD(s) D590-120 220/380 Single/Triple 50 0.25/0.15 55 1400 950 <50 2000-2500 6
GFD(s) D610-120 220/380 Single/Triple 50 0.28/0.16 60 1400 1000 <50 2000-2500 4
GFD(s) D700-120 220/380 Single/Triple 50 0.28/0.16 60 1400 1150 <52 2000-2500 4
GFD(s) D760-120 220/380 Single/Triple 50 0.28/0.16 60 1400 1300 <52 2000-2500 4
GFD(s) D780-120 220/380 Single/Triple 50 0.28/0.16 60 1400 1360 <52 2000-2500 4
GFD(s) D810-120 220/380 Single/Triple 50 0.28/0.16 60 1400 1400 <52 2000-2500 4
GFD(s) D850-120 220/380 Single/Triple 50 0.28/0.16 60 1400 1430 <52 2000-2500 4
GFD(s) D920-120 220/380 Single/Triple 50 0.34/0.19 80 1400 1500 <55 2000-2500 2
GFD(s) D1020-120 220/380 Single/Triple 50 0.34/0.19 80 1400 1600 <55 2000-2500 2
GFD(s) D1120-120 220/380 Single/Triple 50 0.35/0.20 80 1400 1700 <56 2000-2500 2
GFD(s) D1200-120 220/380 Single/Triple 50 0.40/0.20 85 1400 1800 <56 2000-2500 2
GFD(s) D1220-120 220/380 Single/Triple 50 0.40/0.20 85 1400 1850 <56 2000-2500 2
GFD(s) D1300-120 220/380 Single/Triple 50 0.40/0.20 85 1400 1900 <56 2000-3000 2
GFD(s) D1400-120 220/380 Single/Triple 50 0.40/0.20 95 1400 2400 <57 2000-3000 2
GFD(s) D370-150 220/380 Single/Triple 50 0.28/0.16 60 1400 850 <54 630-800 6
GFD(s) D420-150 220/380 Single/Triple 50 0.28/0.16 80 1400 900 <55 800-1600 6
GFD(s) D470-150 220/380 Single/Triple 50 0.28/0.16 80 1400 1200 <55 800-1600 6
GFD(s) D490-150 220/380 Single/Triple 50 0.28/0.16 80 1400 1300 <55 800-1600 6
GFD(s) D590-150 220/380 Single/Triple 50 0.38/0.24 90 1400 1500 <56 1600-2500 6
GFD(s) D650-150 220/380 Single/Triple 50 0.45/0.26 100 1400 1600 <56 2000-3000 6
GFD(s) D780-150 220/380 Single/Triple 50 0.50/0.29 110 1400 2000 <56 2500-3500 6
GFD(s) D850-150 220/380 Single/Triple 50 0.54/0.31 120 1400 2500 <56 2500-3800 6
GFD(s) D650-200 220/380 Single/Triple 50 1.4/0.5 320 1350 2500 <60 1600-2500 6
GFD(s) D780-200 220/380 Single/Triple 50 1.4/0.53 325 1350 3200 <60 3150-4000 6
GFD(s) D850-200 220/380 Single/Triple 50 1.7/0.75 370 1350 3500 <60 4000-5000 6
GFD(s) D900-200 220/380 Single/Triple 50 1.8/0.85 400 1350 3800 <60 5000-8000 6
GFD(s) D1180-200 220/380 Single/Triple 50 2.5/0.95 550 1350 4800 <60 8000-16000 6
GFD(s) D1300-200 220/380 Single/Triple 50 2.7/0.95 600 1350 5500 <60 16000-20000 6

How it works:

This series cooling fan is used in dry type transformer, the fan is placed on both sides of the lower part of the transformer coil, blowing the cold air directly into the coil of the transformer high and low pressure cooling air ducts, the heat dissipation effect is obvious, which can guarantee the normal operation of the transformer and prolong its service life. (Fan start, stop and transformer over-temperature alarm, over-temperature tripping and other functions are provided by the temperature control device).